{"id":250548,"date":"2025-08-26T15:11:49","date_gmt":"2025-08-26T13:11:49","guid":{"rendered":"https:\/\/teleprotekce.ttc.cz\/tp10\/"},"modified":"2026-09-15T16:09:59","modified_gmt":"2026-09-15T14:09:59","slug":"tp10","status":"publish","type":"page","link":"https:\/\/teleprotekce.ttc.cz\/en\/tp10\/","title":{"rendered":"TP10"},"content":{"rendered":"

\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t

PRODUCT<\/h1><\/div>\n\t\t\t<\/div>
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t

TP10<\/o:p><\/span><\/h1><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>
\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t

Fast and reliable communication for high-voltage protection<\/o:p><\/span><\/h2>\n

We provide solutions for preventing losses due to power line failures (short circuits, interruptions, etc.) and avoiding unnecessary shutdowns of related power lines. <\/span><\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t

<\/div>\n\t\t\t<\/div>
\n\t\t\t\t
<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<\/span>\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t

Ensuring reliable protection communication in critically short timeframes<\/span><\/h2>\n

The TP10 device is designed for the transmission of distance protection commands, binary states, and differential protection signals over optical fiber or via PDH\/SDH\/Eth networks. It enables the simultaneous transmission of 10 bidirectional commands and a differential protection signal connected via an optical or electrical interface. Group signal transmission is possible over PDH\/SDH networks, Eth\/IP networks, or directly via optical cable. Transmission reliability can be increased by 1 + 1 transmission path redundancy. <\/span><\/p>\n

Key features include low input impedance for increased noise immunity, sensitivity threshold settings via voltage and time filtering, galvanically isolated inputs and outputs, 8-bit addressing for secure transmission, continuous monitoring of connection and transmission time, transmission routing for up to 4 directions, transmission time starting from 1 ms, a command log with 1 ms recording accuracy, redundant power supply (48 VDC \/ 110 VDC \/ 220 VDC \/ 230 VAC), 820 nm optical interface for differential protection, C37.94, proprietary interfaces (for older SIEMENS, ABB, SEL types), E1\/G.703, Ethernet 100Base-TX, and central or local monitoring (Eth, SNMP).<\/span><\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>

\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\"\"<\/span>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t

Needs<\/h1><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>
\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\"\"<\/span>\n\t\t\t<\/div>
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t

Reliable communication for command transmission<\/h1><\/div>\n\t\t\t<\/div>
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t

Protecting transmission and distribution networks from overload and unnecessary power outages<\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>

\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\"\"<\/span>\n\t\t\t<\/div>
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t

Support for legacy protection types<\/span><\/h1><\/div>\n\t\t\t<\/div>
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t

Support for older proprietary protection systems from various manufacturers<\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>

\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\"\"<\/span>\n\t\t\t<\/div>
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t

Independence from power protection equipment suppliers<\/span><\/h1><\/div>\n\t\t\t<\/div>
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t

Interfaces for various types of protection from different manufacturers<\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>

\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t

SECTOR<\/h1><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>
\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t
\n\t\t\t\t\t
\uf03d<\/span><\/span><\/a><\/div>\n\t\t\t\t\t
\n\t\t\t\t\t\t

Energy and Utilities<\/a><\/h4>\n\t\t\t\t\t\t

Fast and reliable communication for distribution system protection<\/p>\n

More<\/a><\/p><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t